المعجل الخطي، جهاز التعجيل الخطي - Varian - Clinac 600C
القطعة 144154694
هل أنت بائع هذه القطعة? دخول للمزيد من الخيارات.
| وضع: | مفتوح |
| نوع القطعة: | جهاز متكامل |
| فئة: | طب الأورام |
| جهاز: | المعجل الخطي، جهاز التعجيل الخطي |
| المُصنع: | Varian |
| الموديل: | Clinac 600C |
| الحالة: | كما هو |
| سنة التصنيع: | 1995 |
| موقع: | الولايات المتحدة الأمريكية, Connecticut |
| التوفر: | فوري |
| الكمية: | 1 متوفر |
| سعر الوحدة: | 35000 35,000.00 USD |
| | |
![]() | Contact the Seller | ![]() |
![]() | Inspect Before You Buy | ![]() |
توصيف القطعة
VARIAN, 600C w/ 2002 BrainLAB M3 MLC Radiosurgery
Description: Varian 600C plus 2002 BrainLab M3 MLC
Stereotactic Radiotherapy
600C Installed June 1995
Console Software V. 5.4
TOTAL PRICE ONLY $35,000 FOR DEINSTALLED UNIT-- AN UNHEARD OF PRICE FOR A UNIT WHICH INCLUDES THE TOTAL DEINSTALATION COST &
THE COST OF ORIGINAL BASE FRAME REMOVAL WITH THE BASE FRAME INCLUDED IN SALE
--READY TO LOAD LINAC & BASE FRAME ON TRUCK along with 2002 BRAINLAB M3 MLC: Being sold w/ 2002 BrainLAB M3 stereotactic unit
Photon Energy: 6 MV
Beam Hours: <1,300
Dual jaws
ETR Couch
Unit in good working order at time of deinstallation
De-installed Base Frame [Conventional] included
Call to discuss details
SYSTEMS BROKERED have been CRATED and SHIPPED to SATISFIED CLIENTS AT CANCER CENTERS in
INDONESIA, TURKEY, BRAZIL, COLOMBIA, URUGUAY, RUSSIA, and other locations, and to therapy centers, and service companies in the US
REFERENCES AVAILABLE UPON REQUEST.
The m3 high-resolution multileaf collimator, with its fine 3mm leaves at isocenter, has revolutionized radiosurgery by introducing conformal treatments that tailor the dose to the shape of the tumor.
The m3 enables the delivery of superior homogeneous dose distributions with a steep dose gradient – an essential requirement for SRS treatments.
The leaves of the m3 are automatically placed around the target for all beam angles with the desired margin. Risk objects may be automatically protected by the leaves, with manual adjustments able to be made at any time.
Reduced irradiation of normal tissue and the homogeneous dose distribution within the PTV contributes to superior and more efficient patient care.
m3 SETUP
The detachable 'plug and treat' design of the m3 high-resolution multileaf collimator allows fast and easy slide-on attachment to almost any existing linac accessory mount, aided by the storage trolley and with the gantry at the 180° position.
Once m3 is physically mounted to the linear accelerator, the electrical and date connection is immediate.
INTEGRATED SAFETY
The m3 is the only solution fully integrated with Varian accelerators. It communicates with Varian C-Series Clinacs as if it were an internal part of the accelerator, providing superior Clinac safety interlocks, reliability and capabilities such as Dynamic Conformal Arcs and Dynamic IMRT.
Steep dose fall-off - a fundamental requirement for radiosurgery
Multileaf collimators with a leaf thickness of 10 mm are optimized for standard radiotherapy. For stereotactic treatments, a steep dose fall-off is required to protect normal tissue and, in particular, critical structures from high doses.
To accommodate a higher resolution dose delivery, new multileaf collimator designs with 5 mm thick leaves allow the delivery of fractionated stereotactic radiotherapy, but are not generally acceptable for single fraction radiosurgery where special requirements have been defined by the AAPM (1).
The steepness of the dose gradient in radiosurgery is a function of beam geometry and beam penumbra.
Care must be taken to minimize penumbra of the collimator system because the larger the beam penumbra, the shallower the dose fall-off (Figure 1).
For radiosurgery, the recommended limit for dose gradient in the beam penumbra (from 80% to 20%) is greater than or equal to 60%/3 mm (Figure 1).
Fig. 2* [See webpage link supplied for Figures]
Most commercially available multileaf collimators have a penumbra specification from 4 to 8 mm. The m3 with its 3 mm-thin leaves has an effective penumbra of less than 3 mm for all SRS field sizes and meets all SRS requirements (Figure 2).
Thus, the dose can be tailored according to the shape of the lesion, while sparing large amounts of normal healthy tissue.
*An irregular field shape formed from diagonal, straight field edges. Measured 80%, 50% and 20% isodose lines are indicated. A sinusoidal variation in the isodose lines occurs due to the stepping effect between leaf ends and is smallest where the field is formed by the 3 mm thin leaves. Tangents between the 80% and 20% isodose lines show an increasing effective penumbra with increasing leaf thickness.
REFERENCES
AAPM Report No. 54, Stereotactic Radiosurgery, Report of Task Group 42, American Institute of Physics, June 1995 Pike, Podgorsak, et. al., 'Dose distributions in radiosurgery' Medical Physics, Mar/Apr 1990 Cosgrove, et. al., 'Commissioning of a Micro Multi-leaf Collimator and Planning System for SRS.', Radiotherapy & Oncology, (50) 1999
Find your Solution: neurosurgery solutions orthopedic solutions RT/oncology solutions ent solutions spine & trauma solutions integrated OR solutions healthcare IT solutions home print send back m3 High-Resolution Multileaf Collimator
Description: Varian 600C plus 2002 BrainLab M3 MLC
Stereotactic Radiotherapy
600C Installed June 1995
Console Software V. 5.4
TOTAL PRICE ONLY $35,000 FOR DEINSTALLED UNIT-- AN UNHEARD OF PRICE FOR A UNIT WHICH INCLUDES THE TOTAL DEINSTALATION COST &
THE COST OF ORIGINAL BASE FRAME REMOVAL WITH THE BASE FRAME INCLUDED IN SALE
--READY TO LOAD LINAC & BASE FRAME ON TRUCK along with 2002 BRAINLAB M3 MLC: Being sold w/ 2002 BrainLAB M3 stereotactic unit
Photon Energy: 6 MV
Beam Hours: <1,300
Dual jaws
ETR Couch
Unit in good working order at time of deinstallation
De-installed Base Frame [Conventional] included
Call to discuss details
SYSTEMS BROKERED have been CRATED and SHIPPED to SATISFIED CLIENTS AT CANCER CENTERS in
INDONESIA, TURKEY, BRAZIL, COLOMBIA, URUGUAY, RUSSIA, and other locations, and to therapy centers, and service companies in the US
REFERENCES AVAILABLE UPON REQUEST.
The m3 high-resolution multileaf collimator, with its fine 3mm leaves at isocenter, has revolutionized radiosurgery by introducing conformal treatments that tailor the dose to the shape of the tumor.
The m3 enables the delivery of superior homogeneous dose distributions with a steep dose gradient – an essential requirement for SRS treatments.
The leaves of the m3 are automatically placed around the target for all beam angles with the desired margin. Risk objects may be automatically protected by the leaves, with manual adjustments able to be made at any time.
Reduced irradiation of normal tissue and the homogeneous dose distribution within the PTV contributes to superior and more efficient patient care.
m3 SETUP
The detachable 'plug and treat' design of the m3 high-resolution multileaf collimator allows fast and easy slide-on attachment to almost any existing linac accessory mount, aided by the storage trolley and with the gantry at the 180° position.
Once m3 is physically mounted to the linear accelerator, the electrical and date connection is immediate.
INTEGRATED SAFETY
The m3 is the only solution fully integrated with Varian accelerators. It communicates with Varian C-Series Clinacs as if it were an internal part of the accelerator, providing superior Clinac safety interlocks, reliability and capabilities such as Dynamic Conformal Arcs and Dynamic IMRT.
Steep dose fall-off - a fundamental requirement for radiosurgery
Multileaf collimators with a leaf thickness of 10 mm are optimized for standard radiotherapy. For stereotactic treatments, a steep dose fall-off is required to protect normal tissue and, in particular, critical structures from high doses.
To accommodate a higher resolution dose delivery, new multileaf collimator designs with 5 mm thick leaves allow the delivery of fractionated stereotactic radiotherapy, but are not generally acceptable for single fraction radiosurgery where special requirements have been defined by the AAPM (1).
The steepness of the dose gradient in radiosurgery is a function of beam geometry and beam penumbra.
Care must be taken to minimize penumbra of the collimator system because the larger the beam penumbra, the shallower the dose fall-off (Figure 1).
For radiosurgery, the recommended limit for dose gradient in the beam penumbra (from 80% to 20%) is greater than or equal to 60%/3 mm (Figure 1).
Fig. 2* [See webpage link supplied for Figures]
Most commercially available multileaf collimators have a penumbra specification from 4 to 8 mm. The m3 with its 3 mm-thin leaves has an effective penumbra of less than 3 mm for all SRS field sizes and meets all SRS requirements (Figure 2).
Thus, the dose can be tailored according to the shape of the lesion, while sparing large amounts of normal healthy tissue.
*An irregular field shape formed from diagonal, straight field edges. Measured 80%, 50% and 20% isodose lines are indicated. A sinusoidal variation in the isodose lines occurs due to the stepping effect between leaf ends and is smallest where the field is formed by the 3 mm thin leaves. Tangents between the 80% and 20% isodose lines show an increasing effective penumbra with increasing leaf thickness.
REFERENCES
AAPM Report No. 54, Stereotactic Radiosurgery, Report of Task Group 42, American Institute of Physics, June 1995 Pike, Podgorsak, et. al., 'Dose distributions in radiosurgery' Medical Physics, Mar/Apr 1990 Cosgrove, et. al., 'Commissioning of a Micro Multi-leaf Collimator and Planning System for SRS.', Radiotherapy & Oncology, (50) 1999
Find your Solution: neurosurgery solutions orthopedic solutions RT/oncology solutions ent solutions spine & trauma solutions integrated OR solutions healthcare IT solutions home print send back m3 High-Resolution Multileaf Collimator
الأسئلة والأجوبة المتعلقة بهذه القطعة ![]() |
| سؤال | جواب |
| عام: هل كان الجهاز يعمل وفقاً لمواصفات المُصَنِع تماماً قبل تفكيكه؟ | بانتظار الموافقة |
| عام: هل تم التجديد لدى المصنع الأصلي أم لدى أحد وكلائه؟ | بانتظار الموافقة |
| عام: ألا يزال الجهاز غير مفكك؟ | بانتظار الموافقة |
| عام: ما هو تاريخ التجديد؟ | بانتظار الموافقة |
| عام: هل أنت صاحب الجهاز؟ | بانتظار الموافقة |
| عام: هل هناك أضرار واضحة للعيان أو أضرار خفية؟ | بانتظار الموافقة |
| عام: تزويد الطاقة - فازة | بانتظار الموافقة |
| عام: تزويد الطاقة - نطاق الفلتات | بانتظار الموافقة |
| عام: هل يشمل السعر شحن الجهاز؟ | بانتظار الموافقة |
| عام: هل حصل هذا الجهاز / المعدة على مصادقة كاملة من الوكالة الفدرالية الأمريكية للغذاء والدواء (FDA)؟ | بانتظار الموافقة |
| عام: هل يحمل الجهاز / المعدة علامة السلامة الأوروبية؟ | بانتظار الموافقة |
| إرشادات تشغيل ومستندات: هل هناك دليل تشغيل؟ | بانتظار الموافقة |
| إرشادات تشغيل ومستندات: هل هناك ملف معايرة وتكييف؟ | بانتظار الموافقة |
| إرشادات تشغيل ومستندات: هل يوجد ملف لشكاوى الزبائن؟ | بانتظار الموافقة |
| إرشادات تشغيل ومستندات: هل يوجد دليل لخدمة الصيانة؟ | بانتظار الموافقة |
| إرشادات تشغيل ومستندات: هل يوجد سجل لقطع الغيار؟ | بانتظار الموافقة |
| Does M3 come with plan software? How much for M3 only? |
معلومات البيع
| الدفعات التعبئة والتغليف طرق الدفع: تحويل لحساب البنك نسبة الدفعة المقدمة: 10% القطعة غير مرزومة تحقيق يسمح البائع بإجراء تحقيق عن القطعة? نعم متوفر للتحقيق من: فوري |
جميع التفاصيل الواردة على هذه الصفحة قدمها البائع وليس بوسع MedWOW أن تضمن مدى دقتها.
لم تجد ما تبحث عنه؟ انشروا طلبا للشراء
مطالب الشراء هي الطريقة الأمثل للوصول الى بائعين من جميع أنحاء العالم
- إملأ إستمارة بسيطة تزودنا بتفاصيل عن الجهاز الطبي الذي تبحث عنه.
- أحصل على عروض منافسة من باعة عالميين لديهم نفس القطعة التي تبحث عنها.
- اختر أفضل الأسعار وأكثرها توافقاً مع متطلباتك.
شاهد المزيد المعجل الخطي، جهاز التعجيل الخطي اجهزة للبيع


المعجل الخطي، جهاز التعجيل الخطي قد يتم الإشارة إليها أيضاً بصفة: معجل خطي، وحدة العلاج الإشعاعي | IMRT
تفاصيل البائع
موقع: الولايات المتحدة الأمريكية, Connecticut
نوع العمل: وسيط تجاري
Learn More About This Seller
![]() | Get a D&B Report >> |
أدوات الشراء
تتبع هذه القطعة
الكمية المطلوبة
الكمية المتاحة: 1
الرجاء اختيار الكمية التي ترغب بشرائها:
يجب أن تكون الكمية بين 1 - 1
الرجاء انتقاء خيارك
بحوث شائعة
جهاز تصوير مقطعي محوسب، سي.تي سكانرجهاز تصوير بالرنين المغنطيسيجهاز محاكاة العلاج الإشعاعيماسح التَّصْوير المَقْطَعِي بالانبعاث البوزتيرونيشاشات محوسبة للعمليات الجراحية
جهاز أولتراساوند للتشخيصأولتراساوند للقلبأجهزة أولتراساوند مستعملةمقياس كثافة العظام (ثنائي الطاقة)معمل قسطرة
انشر الدعاية | مساعدة | اتصل بنا | مدونة | موارد | ارتبط بموقعنا | منتدى | تشغيل وكالة تجارية | خريطة الموقع
ينطوي استخدام هذا الموقع على الموافقة على عقد المستخدم وكذلك على سياسة الخصوصية الخاصة بشركة MedWOW© 2012 جميع الحقوق محفوظة، MedWOW Ltd.السوق الإلكتروني العالمي لبيع وشراء الأجهزة االطبية المستعملة











